+86-0755-29833888(Shenzhen) +86-0750-2933888(Kaiping)Address:Renda Science and Technology Park, Shiyan Street, Bao'an District, Shenzhen, Guangdong Province
Vector inverter technology is based on DQ axis theory and produced, its basic idea is to decompose the current of the motor into D axis current and Q axis current, where D axis current is excitation current, Q axis current is torque current, so that the AC motor excitation current and torque current can be controlled separately, so that the AC motor has similar control characteristics to the DC motor, is an ideal control theory designed for AC motor, greatly improving the control characteristics of AC motor.
Vector control technology through coordinate transformation, the three-phase system equivalent transformation into M-T two-phase system, the AC motor stator current vector decomposition into two DC components (that is, magnetic flux component and torque component), so as to achieve the purpose of controlling the magnetic flux and torque of AC motor respectively, so as to obtain the same good control effect as DC speed regulation system.
Renda high-performance and high-performance vector control inverter is widely used in industrial, CNC machine tools and other fields.
Renda high-performance and high-performance vector control inverter is widely used in industry, CNC machine tools and other fields, especially milling machines, machining centers and other processing fields.
Renda Electric Industrial Co., Ltd. is a well-known high-tech enterprise specializing in the production of low-voltage inverters, with leading technology and rich management experience in the field of inverters and the spirit of continuous innovation, Renda has maintained a rapid growth trend, and is favored and concerned by customers at home and abroad. The AD300 family of high performance vector converters meets the functional requirements of customer applications:
■The latest high-speed motor control chip DSP is adopted to ensure fast response of vector control
■Modular design of hardware circuit to ensure stable and efficient operation of the circuit
■The exterior design combines the European car design concept, with smooth lines and beautiful appearance
■The structure adopts independent air duct design, the fan can be freely removed, and the heat dissipation is good
■No PG vector control, PG vector control, torque control, V/F control can be selected
■ Powerful input and output multi-function programmable terminal, speed control pulse input, two analog outputs
■The unique adaptive control feature of "excavator" automatically limits the upper limit of motor torque during operation, effectively suppressing frequent tripping of overcurrent
■ Wide voltage input, automatic voltage regulation of output voltage, instantaneous power down without shutdown, stronger adaptability
■ Built-in advanced PID algorithm, fast response, strong adaptability, simple debugging; 16-segment speed control, simple PLC to realize timing, fixed speed, orientation and other multi-function logic control, a variety of flexible control methods to meet a variety of complex working conditions
■Built-in international standard MODBUS RTU ASCII communication protocol, users can control the upper computer through PC/PLC to realize the centralized control of the inverter 485 communication network
Renda inverter specification sheet
power (kW).
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
output
voltage
3-phase O one rated input voltage
rated current (A).
2.5
4.0
6.0
9.0
13
17
25
32
37
45
60
75
90
110
150
overload capacity
constant torque/heavy duty applications: 150% 1 minute, 180% 20 seconds, square torque/light load applications: 120% 1 minute, 150% 1 second
input
rated voltage/frequency
3-phase 380V/440V; 50Hz/60Hz
allowable voltage range
304V-456V voltage imbalance: ≦3%; Permissible volatility: ±5%.
rated current (A).
3.7
5.4
7.0
10.7
15
20.5
27
35
38.5
46.5
62
76
92
113
157
brake unit
standard built-in
needs to be external
protection level
IP20
cooling mode
forced air cooling
power (kW)
90
110
132
160
200
200
250
280
315
355
400
450
500
560
output
voltage (V).
3-phase 0~forehead input voltage
rated current (A).
176
210
250
300
380
420
470
540
600
660
730
840
900
950
overload capacity
constant torque/heavy duty applications 150% 1 minute, 180% 20 seconds, square torque/light load applications: 120% 1 minute, 150% 1 second
input
rated voltage/frequency
3-phase 380V/440V; 50Hz/60Hz
allowable voltage range
304V~456V; Voltage unbalance: ≦3%; Allowable lead rate fluctuations: 5%
rated current [A).
180
214
256
307
385
430
480
548
610
970
610
850
910
960
brake unit
External required
anti-expansion level
IP20
cooling mode
forced air cooling
AD300一T41606/200P及以上产品标配百流电杭器
power [kW).
0.4
0.75
1.5
2.2
output
voltage (V).
single-phase 0 ~ rated input voltage
rated current (A).
2.5
4.5
7
10
overload capacity
150% 1 minute, 180% 20 sec
input
rated voltage/frequency
200V/240V:50Hz/60Hz
allowable voltage/frequency
175V~264V: voltage imbalance: ≤3%; Permissible frequency fluctuations: ±5%.
rated current (A).
5.3
8.3
14
23
brake unit
standard built-in
protection level
IP20
cooling mode
forced air cooling