Renda current vector inverter is a vector control technology through coordinate transformation, the three-phase system equivalent conversion into M-T two-phase system, the AC motor stator current vector decomposition into two DC components (that is, magnetic flux component and torque component), so as to achieve the purpose of controlling the magnetic flux and torque of AC motor respectively, so as to obtain the same good control effect as DC speed regulation system.
Application fields of Randa current vector inverter:
◆Control mode: no PG vector control, V/F control, torque control
Renda inverter specification sheet
power (kW).
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
output
voltage
3-phase O one rated input voltage
rated current (A).
2.5
4.0
6.0
9.0
13
17
25
32
37
45
60
75
90
110
150
overload capacity
constant torque/heavy duty applications: 150% 1 minute, 180% 20 seconds, square torque/light load applications: 120% 1 minute, 150% 1 second
input
rated voltage/frequency
3-phase 380V/440V; 50Hz/60Hz
allowable voltage range
304V-456V voltage imbalance: ≦3%; Permissible volatility: ±5%.
Rated current(A)
3.7
5.4
7.0
10.7
15
20.5
27
35
38.5
46.5
62
76
92
113
157
brake unit
standard built-in
needs to be external
protection level
IP20
cooling mode
forced air cooling
power (kW)
90
110
132
160
200
200
250
280
315
355
400
450
500
560
output
voltage (V).
3-phase 0~forehead input voltage
rated current (A).
176
210
250
300
380
420
470
540
600
660
730
840
900
950
overload capacity
constant torque/heavy duty applications 150% 1 minute, 180% 20 seconds, square torque/light load applications: 120% 1 minute, 150% 1 second
input
rated voltage/frequency
3-phase 380V/440V; 50Hz/60Hz
allowable voltage range
304V~456V; Voltage unbalance: ≦3%; Allowable lead rate fluctuations: 5%
rated current [A).
180
214
256
307
385
430
480
548
610
970
610
850
910
960
brake unit
External required
anti-expansion level
IP20
cooling mode
forced air cooling
AD300-T41606/200P and above products are equipped with 100-current electric hanger
power [kW).
0.4
0.75
1.5
2.2
output
voltage (V).
single-phase 0 ~ rated input voltage
rated current (A).
2.5
4.5
7
10
overload capacity
150% 1 minute, 180% 20 sec
input
rated voltage/frequency
200V/240V:50Hz/60Hz
allowable voltage/frequency
175V~264V: voltage imbalance: ≤3%; Permissible frequency fluctuations: ±5%.
rated current (A).
5.3
8.3
14
23
brake unit
standard built-in
protection level
IP20
cooling mode
forced air cooling